You are here:Home > PRODUCT > Clamp Meter > M266C Digital AC Clamp Meter

M266C Digital AC Clamp Meter

View people:2258

 

This meter is one of a series portable 3 1/2 digital clamp meter for measuring DC and AC Voltage, AC current, resistance, continuity test and insulation test. Some models also provide frequency or temperature test. Full overload protection. Low battery indication and over-range indication are providing. Following table shows function of the series of clamp meter. 

Overview
  • Display: 3 1/2 digit LCD, with automatic polarity indication.
  • Measuring Method: Dual-slope integration A-D converter
  • Overrange Indication: " 1 " Figure only in the display
  • Terminal and earth ground: CAT II 600V
  • Operating temperature: 0℃ to 40℃ (32℉ to 104℉)
  • Storage temperature: -10℃ to 50℃ (14℉ to 122℉)
  • Power: 9V alkaline or carbon-zinc battery(NEDA 1604)
  • Accessories: Operating manual, set of test leads
  • Low Battery Indication: " BAT " to left of display
  • Optional Accessories: Thermocouple (K-type)
  • Dimension:90(W) x 230(D) x 43(H) mm
  • Weight: 320g (including battery)
  • Order Ref. Number: M266CE08
  • Safety Rating: ETL CAT III 600V CAT.II 1000V
Features
  • Display: 2000 counts
  • Jaw Opening: Φ50mm/2.0"
  • Continuity Buzzer: <100Ω
  • Data Hold
  • Low Battery Display
Specs

Specification Range Accuracy

DC Voltage 200mV +-(0.5%+1)
2V/20V/200V +-(0.5%+3)
1000V +-(0.8%+3)
AC Voltage 200V +-(1.0%+5)
750V +-(1.2%+5)
AC Current 20A +-(4.0%+5)
200A +-(2.5%+5)
1000A +-(3.0%+10)
Resistance 200Ω +-(1.0%+5)
2KΩ/20KΩ/200KΩ/2MΩ +-(1.0%+8)
Temperature 0℃~400℃(32℉~752℉) +-(1.0%+3)
401℃~750℃(752℉~1382℉) +-(2.0%+3)
Insulation Test 20MΩ +-(2.0%+2)
2000MΩ(Note<500Ω) +-(4.0%+2)
2000MΩ(Note>500Ω) +-(5.0%+2)

 

Accessories

Supplied with the multimeter


Test Leads                         HYTL-266
Battery                               9V NEDA 1604 or 6F22
Operating Manual               HYS007037

Optional accessory


"K" Type thermocoup              HYTP-010
INSULATION TESTER UNIT     261