You are here:Home > PRODUCT > Digital Multimeters > MS8268 Digital Multimeter

MS8268 Digital Multimeter

View people:7835

Overview
  • Environment conditions:
    1000V CAT. II and 600V CAT. III

    Pollution degree: 2
    Altitude < 2000m
    Operating temperature: 0℃ to 40℃(32℉ to 122℉) (<80%RH,<10℃ non-condensing)
    Storage temperature: -10℃ to 60℃ (14℉ to 140℉) (<70%RH,battery removed)
  • Temperature coefficient: 0.1(specified accuracy) / ℃ (<18℃ or >28℃ )
  • Max. Voltage between terminals and earth ground: 750V AC rms or 1000V DC
  • Fuse protection:
    µA and mA: Resettable fuse (400mA/250V);
    10A F 10A/250ØV 6.3x32 mm
  • Sample Rate: 3 times/sec for digital data.
  • Display: 3 3/4 digits LCD display. Automatic indication of functions and symbols.
  • Range selection: automatic and manual
  • Over range Indication: LCD will display "OL"
  • Low Battery Indication: The '  ' is displayed when the battery is under the proper operation range.
  • Polarity Indication: " " displayed automatically.
  • Power Source: DC 4.5V
  • Battery type: 1.5V AAA.
  • Dimension: 195x92x55mm
  • Weight: approx. 400g (including battery)
Features
  • Display: 4000 counts
  • Auto Ranging
  • Auto Power Off
  • Sound & Light Warning: For incorrectly inserting the input plugs
  • Relative Measurement
  • Transistor hFE : 0~1000
  • Diode: 2.8V
  • Continuity Buzzer: ≤50Ω
  • Data Hold
  • Display Backlight
  • Low Battery Display
Specs

Specification Range Accuracy

DC Voltage 400mV/4V/40V/400V +-(0.7%+2)
1000V +-(0.8%+2)
AC Voltage 400mV +-(3%+3)
4V/40V/400V +-(0.8%+3)
750V +-(1.0%+3)
DC Current 400µA/4000µA/40mA/400mA +-(1.2%+3)
10A +-(2.0%+5)
AC Current 400µA/4000µA/40mA/400mA +-(1.5%+5)
10A +-(3.0%+7)
Resistance 400Ω/4kΩ/40kΩ/400kΩ/4MΩ +-(1.2%+2)
40MΩ +-(2.0%+5)
Capacitance 4nF +-(5.0%+5)
40nF/400nF/4µF/40µF/200µF +-(3.0%+3)
Frequency 9.999Hz~199.9kHz +-(2.0%+5)
Duty Cycle 5%~95% +-(2.0%+2)

 

Accessories
  • User's manual
  • Test Leads: 1KV 10A (model:T3000)
  • Special Multi-function socket