  • Operating environment and condition: 
    1000V CAT.II, 600V CAT.III pollution grade: 2
    Elevation < 2000m
    Environment temperature and humidity: 0~40℃ (< 80% RH, < 10℃, it is not to be considered).
    Storage temperature and humidity: 0~60℃ (<70%RH, remove the battery).
  • Temperature coefficient: 0.1 Accuracy/℃ (<18℃ or >28℃)
  • The maximum allowable voltage between measurement end and ground: 1000V DC or 750V AC RMS
  • Fuse protection: mA grade: Fuse F 250mA/250V; fuse with A grade FF10A/500V.
  • Sampling rate: about 3 times/sec.
  • Display: 3 1/2 digit LCD display, Automatically display unit symbols is accordance with measurement function grade.
  • Over-range indication: LCD will show "1".
  • Low battery indication: When the battery voltage is lower than the normal operating voltage, "" will display on the LCD display.
  • Input polarity indication: automatically display "-" symbol.
  • Power supply: DC 9V
  • Battery type: NEDA 1604, 6F22 or 006P.
  • Outside measurement: 188mm(L)*93mm(W)*50mm(H).
  • Weight: about 380g (include battery).
Features
  • Display: 2000 counts
  • Auto Power Off
  • Transistor hFE: 0~1000
  • Diode: 2.8V
  • Continuity Buzzer: <50Ω
  • Data Hold
  • Low Battery Display
Specs

Specification Range Accuracy

DC Voltage 200mV/2V/20V/200V +-(0.5%+2)
1000V +-(0.8%+2)
AC Voltage 2V/20V/200V +-(0.8%+3)
750V +-(1.2%+3)
DC Current 2mA/20mA +-(0.8%+1)
200mA +-(1.5%+1)
10A +-(2.0%+5)
AC Current 20mA +-(1.0%+5)
200mA +-(1.8%+5)
10A +-(3.0%+7)
Resistance 200Ω +-(0.8%+3)
2KΩ/20KΩ/200KΩ/2MΩ +-(0.8%+2)
20MΩ +-(1.0%+2)
200MΩ +-(6.0%+10)
Capacitance 2nF/20nF/200nF/2µF +-(4.0%+3)
100µF +-(6.0%+10)
Temperature -20℃~0℃ +-(5.0%+4)
1℃~400℃ +-(2.0%+3)
401℃~1000℃ +-(2.0%+5)

 

Accessories
  • Operation Manual: 1 piece
  • Test Probe: 1 piece
  • K-type thermocouple: 1 piece
  • Dedicated multifunction test socket MS3204: 1 piece