You are here:Home > PRODUCT > Circuit Tester > MS112 3 Wire/GFGI Outlet Tester

MS112 3 Wire/GFGI Outlet Tester

View people:1779

Overview
  • AC Voltage Range: 125V AC, 50/60 Hz, 0.3W
  • Overload voltage: CAT II 125V
  • Humidity: <80% relative humidity
  • Operating Temperature: 32℉ to 104℉ (0℃ to 40℃)
  • Storage Temperature: 14℉ to 122℉ (-10℃ to 50℃)
  • Altitude: ~6500 ft. (2000m); indoor use only
  • Dimension: 3.23*1.73*1.26 in. (82*42*32 mm)
  • Weight: Approx. 1.5oz (42g)
  • Safety rating: TL CAT II 125V RoHS
Features

Indicator Fault Reason for Wiring Fault

○  ○ Open Ground Ground contact not connected
○ ○  Open Neutral Neutral contact not connected
○ ○ ○ Open Hot Hot contact not connected
 ○  Hot / Ground Reverse Hot and ground contacts reversed
  ○ Hot / Neutral Reverse Hot and neutral contacts reversed
○ ● ● Correct Receptacle is wired correctly
 

 

Specs

Specification Range

AC Voltage 125V
Operating Temprature 32~104℉(0~40℃)
Operating Humidity <80% relative humidity
 
Accessories
  • User's Manual * 1 piece